Exlar Tritex II Ac Linear Actuator | Actuation Division (2024)

  • Home
  • Industrial - Exlar®
  • Intelligent Drive | Motor | Actuators
  • Tritex T2X AC Linear Actuator

Exlar Tritex II Ac Linear Actuator | Actuation Division (1)

Exlar Tritex II Ac Linear Actuator | Actuation Division (2)

Exlar Tritex II Ac Linear Actuator | Actuation Division (3)

Exlar Tritex II Ac Linear Actuator | Actuation Division (4)

Exlar Tritex II Ac Linear Actuator | Actuation Division (5)

Intelligent Drive | Motor | Actuator

Industrial - Exlar

  • Compact, stand-alone linear motion axis.
  • Easy-to-use, mechanical based configuration software.
  • Continuous force up to 3,225 lbf (14 kN).
  • Speeds up to 800 mm/s (33 in/s).
  • Strokes from 75 to 450 mm (3to 18 in).
  • Voltage classes from 100 - 240 Vac 1-ph.
  • Class 1Division II (C1D2) options available for process control applications with optimized valve configuration software.

More Details

Request A Quote Catalog

Overview

Tritex T2X AC Linear Actuator

Quick Data

ModelsFrame Size mm (in)Stroke inMax Peak Force kN (lbf)Max Continuous Force kN (lbf)
Max Speed mm/s (in/s)
T2X07575 (2.95)
3, 6, 10, 12, 14, 18
8.8 (1,980)4.4 (990)847 (33.33)
T2X09090 (3.54)
3, 6, 10, 12, 18
12.1 (2,700 )6.62 (1,488)847 (33.33)
T2X115115 (4.53)
4, 6, 10, 12, 18
24.0 (5,400)14.3 (3,224)953 (37.5)

By combining the latest electronic power technology with advanced thermal management technology, Exlar sets the benchmark for performance and size. Tritex II Series actuators integrate anAC powered servo drive,digital position controller,brushless servomotorand roller screw linear actuatorin a compact, sealed package. Now you can precisely control motion and solve all of your application requirements with a single, fully integrated device. Simply connect AC power, I/O and communications, speeding up installation and commissioning time resulting in a lower total cost of ownership when compared with other system solutions.

Dramatically Increase Performance

Tritex II electric actuators are the standard for compact, power dense, servo driven devices. These linear actuators incorporate planetary roller screw designs, resulting in envelope sizes that match hydraulic cylinders and 15X the life of comparable ball screw technologies. Whether you are replacing existing fluid power systems or are looking for extending the life if existing electric solutions, Tritex II products can meet your needs.

Significantly Reduce Required Space and Operating Costs

Since the servo drive and digital positioner are housed in a single, sealed package, space requirements are reduced as the need for a control cabinet is eliminated. Without the need for a control cabinet, you can also eliminate the costs and labor-intensive efforts of long cable runs.

Other Advantages

  • IP65S rated for use in harsh environment
  • Maximum power, precision, speed and repeatability in a compact package
  • Engineered for closed loop servo systems
  • 100% duty cycle for hundreds of millions of strokes
  • Hall effect incremental or absolute feedback
  • Sealed housing for extended life and reduced maintenance

AC LINEAR ACTUATORS: APPLICATIONS & OPERATION

Tritex II linear actuators employ a superior inverted roller screw mechanism for converting rotary motion to highly robust and long-life linear motion. These characteristics enable the Tritex actuator to solve applications that previously required pneumatic or hydraulic cylinders. No additional mechanisms (such as acme or ball screws) are necessary to convert the actuator’s rotary power into linear motion to move the load.

The Tritex II linear actuator can be programmed to follow an analog command signal, making it ideal for controlling multiple devices across factory automation, entertainment, or process control applications.

Quick Data

Models:T2M75, T2M90, T2M115 (standard capacity actuators) – Legacy product
T2X75, T2X90, T2X115 (high capacity actuators)
Frame Sizes:3, 3.5, 4.5 in (75, 90, 115 mm)
Stroke Length:3, 4, 6, 10, 12, 14, 18 in (76, 102, 152, 254, 305, 356, 457 mm)
Linear Speed:up to 33.3 in/s (846 mm/s)
Continuous Thrust Capacity:up to 3225 lbf (14 kN)
Standards/Ratings:CE; UL 508 C Type 4 Enclosure; CSA 139; CSA Class I Division 2 Groups A, B, C, D; IP65S standard
Exlar Tritex II Ac Linear Actuator | Actuation Division (15)

Actuator Type
T2X = Tritex II Linear Actuator

BBB = Actuator Frame Size
075 = 75 mm
090 = 90 mm
115 = 115 mm

CC = Stroke Length
03 = 3 inch (76 mm) (N/A T2M/X115)
04 = 4 inch (102 mm) (T2M/X115 only)
06 = 6 inch (152 mm)
10 = 10 inch (254 mm)
12 = 12 inch (305 mm)
14 = 14 inch (356 mm)
18 = 18 inch (457 mm)

DD = Screw Lead (linear travel per screw revolution)
01 = 0.1 inch (2.54 mm)
02 = 0.2 inch (5.08 mm)
05 = 0.5 inch (12.7 mm)
08 = 0.75 inch (19.05 mm) (T2M/X115 only)2

E = Connections
G = Standard Straight Threaded Port with Internal terminals, M20 x 1.5
N = NPT Threaded Port via Adapter with Internal Terminals, 1/2” NPT
I = Intercontec Style - Exlar std, M16/M23 Style Connector

F = Mounting
C = Rear Clevis
D = Double Side Mount
E = Extended Tie Rod
F = Front Flange
G = Metric Rear Clevis
K = Metric Double Side Mount
M = Metric Extended Tie Rod
Q = Metric Side Trunnion
R = Rear Flange
T = Side Trunnion

G = Rod End
A = Male Metric Thread1
B = Female Metric Thread1
F = Female US Standard Thread1
M = Male US Standard Thread1

HH = Feedback Type
HD = Analog Hall Device
IE = Incremental Encoder, 8192 count resolution
AF = Absolute Feedback

III-II = Motor Stator, All 8 Pole
T2X075 Stator Specifications
138-40 = 1 Stack, 230 Vac, 4000 rpm
238-30 = 2 Stack, 230 Vac, 3000 rpm
338-20 = 3 Stack, 230 Vac, 2000 rpm

T2X090 Stator Specifications
138-40 = 1 Stack, 230 Vac, 4000 rpm
238-40 = 2 Stack, 230 Vac, 4000 rpm
238-30 = 2 Stack, 230 Vac. 3000 rpm6

T2X115 Stator Specifications
138-30 = 1 Stack, 230 Vac, 3000 rpm
238-20 = 2 Stack, 230 Vac, 2000 rpm8
238-15 = 2 Stack, 230 Vac, 1500 rpm6, 8(N/A with 0.1” lead)

JJJ = Voltage
230 = 115-230 Vac, single phase

KKK = Option Board
SIO = Standard I/O
IA4 = 4-20 mA Analog I/O
EIP = SIO plus EtherNet/IP w/M12 connector
EIN = SIO plus EtherNet/IP without M12 connector7
PIO = SIO plus PROFINETIO w/M12 connector
PIN = SIO plus PROFINET IO without M12 connector7
TCP = SIO plus Modbus TCP w/M12 connector
TCN = SIO plus Modbus TCP without M12 connector7

MM = Mechanical Options3
AR = External Anti-rotate
L1/2/3 = External Limit Switches4
RB = Rear Brake
PB = Protective Bellows (N/A with extended tie rod mounting option)
SR = Splined Main Rod5

Standard Features
Analog and digital I/O
Built-in positioner
Internal terminals accessible through removable cover
Threaded ports for cable glands (M20)
M12 connector for Ethernet options
RS485 port (M8), Modbus RTU (opto-isolated)
IP65S environmental sealing standard


NOTES:
1. Chrome-plated carbon steel. Threads not chrome-plated.
2. 0.75 lead not available above 12 in stroke.
3. For extended temperature operation consult factory for model number.
4. Limit switch option requires AR option.
5. This option is not sealed and is not suitable for any environment in which contaminants come in contact with actuator and may enter the actuator.
6. N/A with 0.1 in lead
7. Requires customer supplied Ethernet cable through I/O port for Class 1 Division 2 compliance only.
8. Not available with 4 inch stroke.

* Some options are not available with every configuration. For options or specials not listed above contact your local Exlarrepresentative.

L1, L2, L3 = Adjustable External Travel Switch(es)
External travel switches indicate travel to the controller and are adjustable for either the home or end position.*

AR = External Anti-rotate Assembly
This assembly restricts the actuator output rod from rotating when the load is not held by another method. Shorter actuators have a single anti-rotation mechanism; longer lengths have a mechanism on both sides.

RB = Rear Electric Brake
This is a rear, internal holding brake. The rear brake is spring activated and electrically released.

SR = Splined Main Rod
A ball spline shafting main rod with a ball spline nut that replaces the standard front seal and bushing assembly. This rod restricts rotation without the need for an external mechanism. The rod diameter will be the closest metric equivalent to our standard rod sizes. Since this option is NOT sealed, it is not suitable for environments in which contaminants may enter the actuator.

Note: Adding this option affects the overall length and mounting dimensions.

Print

|

Back to top

Product Specifications

T2X075 Performance SpecificationsExlar Tritex II Ac Linear Actuator | Actuation Division (16)

T2X/M075 Mechanical Specifications

Units0.1 Inch Lead
1 Stack2 Stack3 Stack
Continuous Forcelbf (N)589 (2,620)990 (4,404)NA
Peak Forcelbf (N)1,178 (5,240)1,980 (8,808)***NA
Max Speedin/sec (mm/sec)6.67 (169)5.00 (127)NA
T2X - C_a
(Dynamic Load Rating)
lbf (N)5516 (24536)5516 (24536)NA
T2M**** - C_a
(Dynamic Load Rating)
lbf (N)3310 (14724)3310 (14724)NA
Units0.2 Inch Lead
1 Stack2 Stack3 Stack
Continuous Forcelbf (N)334 (1,486)561 (2,496)748 (3,327)
Peak Forcelbf (N)668 (2,971)1,122 (4,991)1,495 (6,650)
Max Speedin/sec (mm/sec)13.33 (339)10.00 (254)6.67 (169)
T2X - C_a
(Dynamic Load Rating)
lbf (N)5800 (25798)5800 (25798)5800 (25798)
T2M**** - C_a
(Dynamic Load Rating)
lbf (N)3570 (15880)3570 (15880)3570 (15880)
Units0.5 Inch Lead
1 Stack2 Stack3 Stack
Continuous Forcelbf (N)141 (627)238 (1,059)317 (1,410)
Peak Forcelbf (N)283 (1,259)475 (2,113)633 (2,816)
Max Speedin/sec (mm/sec)33.33 (847)25.00 (635)16.67 (423)
T2X - C_a
(Dynamic Load Rating)
lbf (N)4900 (21795)4900 (21795)4900 (21795)
T2M**** - C_a
(Dynamic Load Rating)
lbf (N)3016 (13416)3016 (13416)3016 (13416)
UnitsUniversal Specifications
SpeedRPM @ 240 VAC400030002000
Drive Current @
Continuous Force
Amps3.13.83.6
Available Stroke
Lengths
in (mm)3 (76), 6 (152), 10 (254), 12 (305), 14 (356), 18 (457)
Inertia
(zero stroke)
lb-in-s^2/ Kg-m^20.002655 (0.000003000)0.002829 (0.000003196)0.003003 (0.0000033963)
Inertia Adder
(per inch of stroke)
lb-in-s^2/in/ Kg-m^2/in0.0001424 (0.0000001609)0.0001424 (0.0000001609)0.0001424 (0.0000001609)
Inertia Adder
(per inch of stroke)
lb (kg)10.8 (4.9) for 3 inch stroke, 1 stack. Add 1.1 (0.5) per inch of stroke.Add 1.1 (0.5) per motor stack.
Add .8 (0.4) for brake.
Operating
Temperature
Range*
-20C to 65C(-40˚C available, consult Exlar)
Continuous AC
Input Current**
Amps4.343.6

* Ratings based on 40˚C ambient conditions
** Continuous input current rating is defined by UL and CSA
*** T2X peak force for 0.1 inch lead is 1980 lbf (8808 N). T2M peak force for 0.1 inch lead limited to 1620 lbf (7206 N).
**** M products restricted to reorders only, no new configurations

T2X090 Performance SpecificationsExlar Tritex II Ac Linear Actuator | Actuation Division (21)

T2X/M090 Mechanical Specifications

Units0.1 Inch Lead
1 Stack2 Stack2 Stack
Continuous Forcelbf (N)1,130 (5062)1,488 (6619)NA
Peak Forcelbf (N)2,260 (10053)2,700 (12010)***NA
Max Speedin/sec (mm/sec)6.67 (169)6.67 (169)NA
T2X - C_a
(Dynamic Load Rating)
lbf (N)5516 (24536)5516 (24536)NA
T2M**** - C_a
(Dynamic Load Rating)
lbf (N)3310 (14724)3310 (14724)NA
Units0.2 Inch Lead
1 Stack2 Stack2 Stack
Continuous Forcelbf (N)640 (2847)843 (3750)1,113 (4951)
Peak Forcelbf (N)1,281 (5698)1,687 (7504)2,225 (9897)
Max Speedin/sec (mm/sec)13.33 (338)13.33 (338)10.00 (254)
T2X - C_a
(Dynamic Load Rating)
lbf (N)5800 (25798)5800 (25798)5800 (25798)
T2M**** - C_a
(Dynamic Load Rating)
lbf (N)3570 (15880)3570 (15880)3570 (15880)
Units0.5 Inch Lead
1 Stack2 Stack2 Stack
Continuous Forcelbf (N)271 (1205)357 (1588)471 (2095)
Peak Forcelbf (N)542 (2410)714 (3176)942 (4190)
Max Speedin/sec (mm/sec)33.33 (846)33.33 (846)25.00 (635)
T2X - C_a
(Dynamic Load Rating)
lbf (N)4900 (21795)4900 (21795)4900 (21795)
T2M**** - C_a
(Dynamic Load Rating)
lbf (N)3016 (13416)3016 (13416)3016 (13416)
UnitsUniversal Specifications
SpeedRPM @ 240 VAC400040003000
Drive Current @
Continuous Force
Amps5.77.57.5
Available Stroke Lengthsin (mm)3 (76), 6 (152),10 (254), 12 (305),18 (457)
Inertia (zero stroke)lb-in-s^2/ Kg-m^20.002655 (0.000003000)0.002829 (0.000003196)0.003003 (0.0000033963)
Inertia Adder (per inch of stroke)lb-in-s^2/in/ Kg-m^2/in0.0001424 (0.0000001609)0.0001424 (0.0000001609)0.0001424 (0.0000001609)
Approximate Weightlb (kg)14 (6.35) for 3 inch stroke, 1 stack.Add 1 (0.5) per inch of stroke.Add 3 (1.4) per motor stack.Add 3 (1.4) for brake.
Operating Temperature Range*-20 to 65˚ C (-40˚C available, consult Exlar)
Continuous AC Input Current**Amps6.36.36.3

* Ratings based on 40˚C ambient conditions
** Continuous input current rating is defined by UL and CSA
*** T2X peak force for 0.1 inch lead is 1980 lbf (8808 N). T2M peak force for 0.1 inch lead limited to 1620 lbf (7206 N).
**** M products restricted to reorders only, no new configurations

T2X115 Performance SpecificationsExlar Tritex II Ac Linear Actuator | Actuation Division (26)

T2X/M115 Mechanical Specifications

Units0.1 Inch Lead
1 Stack2 Stack2 Stack
Continuous Forcelbf (N)2,060 (9,163)3,224 (14,341)NA
Peak Forcelbf (N)4,120 (18,327)5,400 (24,020)***NA
Max Speedin/sec (mm/sec)5.00 (127)3.33 (84)NA
T2X - C_a
(Dynamic Load Rating)
lbf (N)7900 (35141)7900 (35141)NA
T2M**** - C_a
(Dynamic Load Rating)
lbf (N)4736 (21067)4736 (21067)NA
Units0.2 Inch Lead
1 Stack2 Stack2 Stack
Continuous Forcelbf (N)1,177 (5,235)1,843 (8,198)2,380 (10,586)
Peak Forcelbf (N)2,354 (10,471)3,685 (16,392)4,760 (21,174)
Max Speedin/sec (mm/sec)10.00 (254)6.67 (169)5.00 (127)
T2X - C_a
(Dynamic Load Rating)
lbf (N)8300 (36920)8300 (36920)8300 (36920)
T2M**** - C_a
(Dynamic Load Rating)
lbf (N)4890 (21751)4890 (21751)4890 (21751)
Units0.5 Inch Lead
1 Stack2 Stack2 Stack
Continuous Forcelbf (N)530 (2,358)829 (3,688)1,071 (4,764)
Peak Forcelbf (N)1,059 (4711)1,658 (7,375)2,142 (9,528)
Max Speedin/sec (mm/sec)25.00 (635)16.67 (423)12.50 (317)
T2X - C_a
(Dynamic Load Rating)
lbf (N)7030 (31271)7030 (31271)7030 (31271)
T2M**** - C_a
(Dynamic Load Rating)
lbf (N)4218 (18763)4218 (18763)4218 (18763)
Units0.75 Inch Lead
1 Stack2 Stack2 Stack
Continuous Forcelbf (N)353 (1,570)553 (2,460)714 (3,176)
Peak Forcelbf (N)706 (3,140)1,106 (4,920)1,428 (6,352)
Max Speedin/sec (mm/sec)37.5 (953)25 (635)17.75 (450)
T2X - C_a
(Dynamic Load Rating)
lbf (N)6335 (28179)6335 (28179)6335 (28179)
T2M**** - C_a
(Dynamic Load Rating)
lbf (N)3328 (14804)3328 (14804)3328 (14804)
UnitsUniversal Specifications
SpeedRPM @ 240 VAC300020001500
Drive Current @
Continuous Force
Amps8.58.58.5
Available Stroke Lengthsin (mm)4 (102), 6 (152),10 (254), 12 (305), 18 (457)
Inertia (zero stroke)lb-in-s2/ Kg-m20.01132 (0.000012790)0.01232 (0.00001392)0.01332 (0.00001505)
Inertia Adder
(per inch of stroke)
lb-in-s2/in/ Kg-m2/in0.0005640 (0.0000006372)0.0005640 (0.0000006372)0.0005640 (0.0000006372)
Approximate Weightlb (kg)34 (15.5) for 6 inch stroke, 1 stack.Add 2 (1) per inch of stroke.Add 8 (4) per motor stack.Add 4 (2) for brake.
Operating Temperature Range*-20 to 65˚ C (-40˚C available, consult Exlar)
Continuous AC Input Current**Amps8.38.38.3

* Ratings based on 25˚C conditions.
** Continuous input current rating is defined by UL and CSA
*** T2X peak force for 0.1 inch lead is 5400 lbf (24,020 N). T2M peak force for 0.1 inch lead limited to 3966 lbf (17,642 N)
**** Legacy Product.

Find more resources in ourInfoCenter.

How can we help?

Can the Tritex II linear actuators replace hydraulic cylinders?Exlar Tritex II Ac Linear Actuator | Actuation Division (31)

Tritex actuators have similar capabilities as a comparably sized hydraulic cylinders but without the cost or maintenance issues. High force, fast speeds, and precise movements make it a superior substitute for hydraulic applications

Does the AC Linear Actuator make an ideal hydraulic replacement?Exlar Tritex II Ac Linear Actuator | Actuation Division (32)

Tritex actuators have the same capabilities as a hydraulic equivalent but without the cost or maintenance issues. High force, fast speeds, and precise movements make it a superior substitute for hydraulic applications.

Is the Tritex Series an Industry 4.0 IoT actuator?Exlar Tritex II Ac Linear Actuator | Actuation Division (33)

The Tritex II Series actuators are intelligent actuators incorporating on-board control and communications capabilities, enabling support for distributed control and IIoT architectures

  • Production Efficiencies (speed, up-time, duty cycle)
  • Environmental Sustainability (energy efficiency, reduction in hazardous materials)
  • Agile & Adaptable Processes (configurability, connectivity)
  • Fully Autonomous Operation (distributed control, predictive maintenance)

What are the primary benefits of using an electric actuator system over hydraulics?Exlar Tritex II Ac Linear Actuator | Actuation Division (34)

Electric actuators offer high speed and force, are flexible and easily programmable for a variety of load conditions, have high accuracy and repeatability, are efficient, simple to install, require little maintenance, and are environmentally friendly.

By not using a hydraulic system, the user can eliminate oil leaks, reduce pollution, and improve worker safety. Electric actuators are also a non-toxic solution, especially in the food industry

What features does the Tritex II AC Linear Actuator have?Exlar Tritex II Ac Linear Actuator | Actuation Division (35)

The AC-powered Tritex II actuators contain a 1.5 kW servo amplifier and an on-board motion controller. With standard features such as analog following for position, compound moves, move chaining, and individual force/torque control for each move, the Tritex II can solve many of your motion control challenges.

What temperature can the Tritex II AC Linear Actuator Hold?Exlar Tritex II Ac Linear Actuator | Actuation Division (36)

The Tritex II with AC power electronics operates with maximum reliability over a broad range of ambient temperatures: -40˚C to +65˚C.

Please log in or register to use our quote request tool, with this you can view and download 3D and 2D models and drawings, as well as build and submit a quote request.

If you do not have a login, please proceed to the registration page

Register

If you currently have an Exlar website account and would like to delete it, please contact

Exlar Tritex II Ac Linear Actuator | Actuation Division (2024)
Top Articles
Latest Posts
Article information

Author: Nicola Considine CPA

Last Updated:

Views: 5777

Rating: 4.9 / 5 (69 voted)

Reviews: 84% of readers found this page helpful

Author information

Name: Nicola Considine CPA

Birthday: 1993-02-26

Address: 3809 Clinton Inlet, East Aleisha, UT 46318-2392

Phone: +2681424145499

Job: Government Technician

Hobby: Calligraphy, Lego building, Worldbuilding, Shooting, Bird watching, Shopping, Cooking

Introduction: My name is Nicola Considine CPA, I am a determined, witty, powerful, brainy, open, smiling, proud person who loves writing and wants to share my knowledge and understanding with you.